首页 Texas Instruments(德州仪器) 模拟电流检测放大器 INA303-Q1
型号INA303-Q1 |
品牌 |
分类模拟电流检测放大器 |
描述具有窗口比较器的 AEC-Q100、36V、双向、550kHz、4V/µs 高精度电流感应放大器 |
|
产品概述参数 Product type | Analog output with integrated comparator | Common-mode voltage (max) (V) | 36 | Common-mode voltage (min) (V) | 0 | Input offset (±) (max) (V) | 0.00003, 0.00005, 0.00008 | Input offset drift (±) (typ) (V/°C) | 0.0000001 | Voltage gain (V/V) | 20, 50, 100 | CMRR (min) (dB) | 100 | Bandwidth (MHz) | 0.45, 0.5, 0.55 | Supply voltage (max) (V) | 5.5 | Supply voltage (min) (V) | 2.7 | Iq (max) (mA) | 1.1 | Number of channels | 1 | Comparators (#) | 2 | Gain error (%) | 0.1, 0.15, 0.2 | Gain error drift (±) (max) (ppm/°C) | 10 | Slew rate (V/µs) | 4 | Features | Alert Function, Bi-directional, High precision, Low-side Capable | Rating | Automotive | TI functional safety category | Functional Safety-Capable | Operating temperature range (°C) | -40 to 125 |
封装 | 引脚 | 尺寸 TSSOP (PW) | 14 | 32 mm² 5 x 6.4 |
特性 - 符合面向汽车应用的 AEC-Q100 标准
- 温度等级 1:-40°C ≤ TA ≤ +125°C
- HBM ESD 分类等级 2
- CDM ESD 分类等级 C6
- 提供功能安全
- 宽共模输入范围:-0.1V 至 +36V
- 两个比较器输出:
- INA302 -Q1:两个独立的超限警报
- INA303 -Q1:窗口比较器
- 阈值电平单独设置
- 比较器 1 警报响应:1µs
- 比较器 2 可调延迟:2µs 至 10s
- 具有独立锁存控制模式的开漏极输出
- 高准确度放大器:
- 失调电压:30µV(最大值,A3 版本)
- 失调电压漂移:0.5µV/°C(最大值)
- 增益误差:0.15%(最大值,A3 版本)
- 增益误差漂移:10ppm/°C
- 可用放大器增益:
- INA302A1 -Q1,INA303A1 -Q1:20V/V
- INA302A2 -Q1,INA303A2 -Q1:50V/V
- INA302A3 -Q1,INA303A3 -Q1:100V/V
说明 INA302 -Q1 和 INA303 -Q1 (INA30x -Q1) 器件具有一个高共模、双向、电流感应放大器和两个高速比较器,用于检测超出范围的电流状况。INA302 -Q1 比较器配置为检测和响应过流状况。INA303 -Q1 比较器在窗口配置中配置为响应过流和欠流状况。这些器件使用外部限位设置电阻器,对每个比较器设置都具有可调限位阈值范围。这些电流分流监控器可在独立于电源的 –0.1V 至 +36V 共模电压范围内测量差动电压信号。 此外,这些器件还将承受高达 40V 的共模电压。 开漏极警报输出可配置为在透明模式(输出状态与输入状态保持一致)或锁存模式(警报输出在锁存复位时清除)下运行。比较器 1 的警报响应时间小于 1µs,而比较器 2 的警报响应时间通过外部电容器进行设置,范围介于 2µs 至 10s 之间。 这些器件由单个 2.7V 至 5.5V 电源供电,消耗的最大电源电流为 950µA。这些器件具有 –40°C 至 +125°C 的扩展额定工作温度范围,并且采用 14 引脚 TSSOP 封装。 |