首页 Texas Instruments(德州仪器) 通用运算放大器 TL081H
型号TL081H |
品牌 |
分类通用运算放大器 |
描述工作温度范围为 -40°C 至 125°C 且输入接近 V+ 的单路、40V、5.25MHz、4mV 失调电压、20V/µs 运算放大器 |
|
产品概述参数 Number of channels | 1 | Total supply voltage (+5 V = 5, ±5 V = 10) (max) (V) | 40 | Total supply voltage (+5 V = 5, ±5 V = 10) (min) (V) | 4.5 | Rail-to-rail | In to V+ | GBW (typ) (MHz) | 5.25 | Slew rate (typ) (V/µs) | 20 | Vos (offset voltage at 25°C) (max) (mV) | 4 | Iq per channel (typ) (mA) | 0.9375 | Vn at 1 kHz (typ) (nV√Hz) | 37 | Rating | Catalog | Operating temperature range (°C) | -40 to 125 | Offset drift (typ) (V/°C) | 0.000002 | Features | Cost Optimized, EMI Hardened, Standard Amps | Input bias current (max) (pA) | 120 | CMRR (typ) (dB) | 105 | Iout (typ) (A) | 0.026 | Architecture | CMOS | Input common mode headroom (to negative supply) (typ) (V) | 1.5 | Input common mode headroom (to positive supply) (typ) (V) | 0 | Output swing headroom (to negative supply) (typ) (V) | 0.105 | Output swing headroom (to positive supply) (typ) (V) | 0.115 |
封装 | 引脚 | 尺寸 SOIC (D) | 8 | 29.4 mm² 4.9 x 6 | SOT-23 (DBV) | 5 | 8.12 mm² 2.9 x 2.8 | SOT-SC70 (DCK) | 5 | 2.5 mm² 2 x 1.25 |
特性 - High slew rate: 20 V/µs (TL08xH, typ)
- Low offset voltage: 1 mV (TL08xH, typ)
- Low offset voltage drift: 2 µV/°C
- Low power consumption: 940 µA/ch (TL08xH, typ)
- Wide common-mode and differential voltage ranges
- Common-mode input voltage range includes VCC+
- Low input bias and offset currents
- Low noise: Vn = 18 nV/√Hz (typ) at f = 1 kHz
- Output short-circuit protection
- Low total harmonic distortion: 0.003% (typ)
- Wide supply voltage: ±2.25 V to ±20 V, 4.5 V to 40 V
说明 The TL08xH (TL081H, TL082H, and TL084H) family of devices are the next-generation versions of the industry-standard TL08x (TL081, TL082, and TL084) devices. These devices provide outstanding value for cost-sensitive applications, with features including low offset (1 mV, typical), high slew rate (20 V/µs), and common-mode input to the positive supply. High ESD (1.5 kV, HBM), integrated EMI and RF filters, and operation across the full –40°C to 125°C enable the TL08xH devices to be used in the most rugged and demanding applications. |